Stationary Concrete Pumps

Leinfra stationary concrete pumps are engineered to deliver reliable, high-pressure concrete pumping for infrastructure, industrial, and high-rise construction projects. The LCP Series from Leinfra is designed to perform consistently under real site conditions, offering durability, safety, and long service life.

Product Overview

The LCP Series stationary concrete pumps are built for projects that require precise concrete delivery over long horizontal and vertical distances. These pumps are suitable for urban construction, infrastructure development, and industrial applications where consistent output and operational reliability are critical.

Key Feature Comparison

Feature LCP 1205 E LCP 1407 D
Variable Displacement Pump Yes Yes
Heavy-Duty Valve System Yes Yes
Separate Hydraulic Circuits Yes Yes
Centralized Lubrication Yes Yes
Emergency Stop System Yes Yes
Motor / Engine Overload Protection Yes Yes

Performance Comparison – LCP 1205 E vs LCP 1407 D

Parameter LCP 1205 E LCP 1407 D
Power Type Electric Diesel
Output (m³/h) 55 / 37 60 / 88
Delivery Pressure (bar) 57 / 85 60 / 90
Cylinder Stroke 1200 mm 1400 mm
Strokes per Minute 14 / 21 24 / 36
Motor / Engine Power 55 kW 74 kW
Hopper Capacity 600–700 L 600–700 L
Machine Weight 4100 kg 4600 kg
Max Horizontal Delivery 400–500 m 500–600 m
Max Vertical Delivery 100–120 m 120–150 m

Technical Specifications Comparison

Specification LCP 1205 E LCP 1407 D
Output (m³/h) 55 / 37 60 / 88
Delivery Pressure (bar) 57 / 85 60 / 90
Cylinder Stroke 1200 mm 1400 mm
Engine / Motor Power 55 kW (Electric) 74 kW (Diesel)
Hopper Capacity 600–700 L 600–700 L
Max Horizontal Delivery 400–500 m 500–600 m
Max Vertical Delivery 100–120 m 120–150 m

Safety Features (Both Models)

Safety Feature Availability
Emergency Stop System Standard
Hydraulic Lockout Valve Standard
Pressure Relief Valve Standard
Motor / Engine Overload Protection Standard

Safety and system protection are built-in priorities across the entire LCP Series.

Application Areas

High-rise residential and commercial construction
Roads, flyovers, and bridges
Metro rail and tunnel projects
Precast concrete plants
Power plants and industrial foundations
Urban as well as remote site operations

Accessories & Customization

Standard Accessories

  • Tungsten carbide wear parts
  • S-Valve 2018PN
  • DN150 to DN125 reducer pipe
  • Rubber hopper bead
  • Maintenance footrest
  • DN150 hard pipeline cleaning ball
  • Hose clamp (cup tension type)
  • O-ring kit with tool set
  • Centralized lubrication system

Optional Accessories

  • DN 125 seamless pipelines and bends
  • Auto greasing system (12V)
  • 4 m end hose with cleaning ball
  • Pipeline cleaning pig
  • Air compressor for pipeline cleaning

Which Model Should You Choose?

Choose LCP 1205 E if:

1. Reliable electrical power is available
2. The project is in an urban or noise-sensitive environment
3. Controlled, efficient pumping is required

Choose LCP 1407 D if:

1. The site is remote or off-grid
2. Higher output and longer pumping distances are needed
3. Independent power and operational flexibility are critical

Get Product Consultation

Leinfra provides application-based technical guidance to help you select the right stationary concrete pump based on site conditions, pumping distance, concrete mix, and project scale.

Leinfra – Trusted Solutions for Every Concrete Application

Frequently Asked Questions

What is the difference between LCP 1205 E and LCP 1407 D?

The main difference lies in the power source and application suitability.
LCP 1205 E is an electric stationary concrete pump suited for sites with reliable power supply and lower noise requirements.
LCP 1407 D is a diesel-powered model designed for remote, off-grid, and heavy infrastructure projects requiring higher output and longer pumping distances.

Which model is better for high-rise construction?

For urban high-rise buildings with stable electrical power, LCP 1205 E is typically preferred due to controlled output and lower noise levels.
For large-scale or high-demand high-rise projects, especially where power availability is uncertain, LCP 1407 D may be more suitable.

Can these pumps handle coarse or stiff concrete mixes?

Yes. Both LCP 1205 E and LCP 1407 D are engineered with a heavy-duty valve system and variable displacement pump, allowing them to handle coarse and stiff concrete mixes efficiently under demanding site conditions.

What is the maximum pumping distance supported by the LCP series?

  • LCP 1205 E:
    Horizontal delivery up to 400–500 meters and vertical delivery up to 100–120 meters
  • LCP 1407 D:
    Horizontal delivery up to 500–600 meters and vertical delivery up to 120–150 meters

Actual performance depends on concrete mix design, pipeline configuration, and site conditions.

Are safety features included as standard?

Yes. Both models come with standard safety features, including emergency stop systems, hydraulic lockout valves, pressure relief valves, and motor or engine overload protection to ensure operator safety and equipment protection.

Can the pumps be customized for specific project requirements?

Yes. Leinfra offers accessories and configuration support, including pipeline options, auto greasing systems, cleaning accessories, and application-based guidance to match specific site and project needs.

Which pump is suitable for remote or off-grid locations?

LCP 1407 D is ideal for remote or off-grid locations as it operates independently using a diesel engine, making it suitable for infrastructure, bridge, tunnel, and industrial projects without reliable power access.

Do these pumps support continuous-duty operation?

Yes. Both LCP models are designed for continuous-duty cycles, making them suitable for long working hours in infrastructure, industrial, and large concrete placement projects.

How do I choose the right model for my project?

Choosing the right model depends on:

  • Power availability at site
  • Required output and pumping distance
  • Project scale and duration
  • Site accessibility and environment

For best results, technical consultation is recommended before final selection.